Search

/produkte/alr5200-168

ALR.5.200/..

...download area).Installation by our own fitters recommended. Technical data Material/sheet thickness: 3 mm Supply length: 3 mtr Steel grating width: 200 mm Designs Article No. Channel height (h) Recess (BxT) ALR.5.200/50 50 mm 320 x 60 mm ALR.5.200/60 60 mm 320 x 70 mm ALR.5.200/80 80 mm 320 x 95...
/produkte/alr5250-223

ALR.5.250/..

...download area).Installation by our own fitters recommended. Technical data Material/sheet thickness: 3 mm Supply length: 3 mtr Steel grating width: 250 mm Designs Article No. Channel height (h) Recess (BxT) ALR.5.250/60 60 mm 370 x 70 mm ALR.5.250/80 80 mm 370 x 95 mm ALR.5.250/100 100 mm 370 x...
/produkte/flr5120-339

FLR.5.120/..

...download area).Installation by our own fitters recommended. Technical data Material/sheet thickness: 3 mm Supply length: 3 mtr Slotted grating width: 120 mm Designs Article No. Channel height (h) Recess (BxT) FLR.5.120/30 30 mm 240 x 40 mm Subject to technical change without notice FLR.5.120...
/produkte/flr5150-342

FLR.5.150/..

...download area).Installation by our own fitters recommended. Technical data Material/sheet thickness: 3 mm Supply length: 3 mtr Slotted grating width: 150 mm Designs Article No. Channel height (h) Recess (BxT) FLR.5.150/30 30 mm 270 x 40 mm Subject to technical change without notice FLR.5.150...
/produkte/bal2-453

BAL.2.

... screed, bitumen welding membrane, liquid plastic trafficability C250 (D400 or E600 on request) Notes Drainage slots are possible (on request).For stainless steel, the general cleaning and care instructions must be observed (see also download area).Flange also available as square.Also...
/produkte/bal8-455

BAL.8.

...Types coating, concrete, screed, liquid plastic trafficability C250 (D400 or E600 on request) Notes For stainless steel, the general cleaning and care instructions must be observed (see also download area).Flange also available as square.Also available in 8 mm and 10 mm thickness.Floor...
/produkte/al511-176

AL.5.11/..

...Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 4 mm (±2 mm) Visible width: 11 mm Maximal joint width: 8 mm Load rating...
/produkte/al521020-177

AL.5.210/20

...Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 30 mm (-10/+20 mm) Movement vertical: 10 mm (±5 mm) Visible width: 210 mm...
/produkte/al618522-2

AL.6.185/22

...Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 10 mm (±5 mm) Movement vertical: 8 mm (±4 mm) Visible width: 180 mm...
/produkte/al625522-71

AL.6.255/22

...Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 10 mm (±5 mm) Movement vertical: 8 mm (±4 mm) Visible width: 250 mm...
/produkte/st616519-190

ST.6.165/19

...Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 30 mm (-10/+20 mm) Visible width: 165 mm Maximal joint width: 15 mm Load...
/produkte/st619019-431

ST.6.190/19

...Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 35 mm (-15/+20 mm) Visible width: 190 mm Maximal joint width: 40 mm Load...
/produkte/st623019-191

ST.6.230/19

...Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 35 mm (-15/+20 mm) Visible width: 230 mm Maximal joint width: 80 mm Load...
/produkte/va6110-116

VA.6.110/..

...Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 13 mm (-5/+8 mm) Visible width: 108 mm Maximal joint width: 30 mm Load...
/produkte/va6165-115

VA.6.165/..