Search
/produkte/va7110-162
VA.7.110/..
...joints in highly stressed industrial concrete floors, continuous load transfer (thus preventing load-related height offset) Applications all industrial applications Material substructure hot-dip galvanised steel and visible surface stainless steel V2A (V4A on request), EPDM cellular rubber in...
/produkte/st7110-161
ST.7.110/..
...joints in highly stressed industrial concrete floors, continuous load transfer (thus preventing load-related height offset) Applications all industrial applications Material black steel, EPDM cellular rubber in the central section Covering Types concrete, industrial coverings trafficability...
/datenschutz
Privacy policy
...keine Cookies auf Ihrem Computer gespeichert werden oder stets ein Hinweis erscheint, bevor ein neuer Cookie angelegt wird. Die vollständige Deaktivierung von Cookies kann jedoch dazu führen, dass Sie nicht alle Funktionen unserer Website nutzen können. Plausible Analytics Plausible Analytics ist...
/produkte/al521020-177
AL.5.210/20
...parts corner piece, T-piece, cross piece Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 30 mm (-10/+20 mm) Movement...
/produkte/al618522-2
AL.6.185/22
...parts corner piece, T-piece, cross piece Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 10 mm (±5 mm) Movement vertical: 8...
/produkte/al625522-71
AL.6.255/22
...parts corner piece, T-piece, cross piece Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 10 mm (±5 mm) Movement vertical: 8...
/produkte/va615015-49
VA.6.150/15
... cross piece, floor-wall connections Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 10 mm (±5 mm) Movement vertical: 3...
/produkte/va616519-50
VA.6.165/19
... cross piece, floor-wall connections Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 30 mm (-10/+20 mm) Visible width...
/produkte/st616519-190
ST.6.165/19
... cross piece, floor-wall connections Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 30 mm (-10/+20 mm) Visible width...
/produkte/va619019-429
VA.6.190/19
... cross piece, floor-wall connections Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 35 mm (-15/+20 mm) Visible width...
/produkte/st619019-431
ST.6.190/19
... cross piece, floor-wall connections Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 35 mm (-15/+20 mm) Visible width...
/produkte/va623019-72
VA.6.230/19
... cross piece, floor-wall connections Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 35 mm (-15/+20 mm) Visible width...
/produkte/st623019-191
ST.6.230/19
... cross piece, floor-wall connections Notes Depending on the floor covering, we recommend installing a grouting seal between the joint profile and the covering to prevent the hairline crack caused by the building physics. Technical data Movement horizontal: 35 mm (-15/+20 mm) Visible width...
/produkte/va895-1
VA.8.95/..
...from the sides.Installation by our own fitters recommended. Technical data Movement horizontal: 40 mm (±20 mm) Movement vertical: 20 mm (±10 mm) Visible width: 95 mm Maximal joint width: 60 mm Load rating: wheel load 4500 kg up to Ø 150 mm, B = 100 mm Load rating trucks: 600 kN (DIN 1072) Load...
/produkte/va8115-13