Floor-Wall constructions
Professional construction of building joints along rising building components (such as columns).
Floor-Wall construction W1
Profile design Floor-Wall connection W1
for expansion joints on rising building components with mounting
bracket upwards.
Raise of the waterproofing membrane to 150 mm above the
upper edge of the Profile (flashing on request).
System example: VA.8.95/52 F W1

Fitting Floor-Wall connection W1
if the expansion joint passes directly on rising building components,
there are at the transition from floor-floor to floor-wall
two corner pieces horizontally required (Z-shaped design).
System example: VA.8.95/52 F W1

Profile design Floor-Wall connection W1
for expansion joints offset to rising building components with mounting
bracket upwards.
Raise of the waterproofing membrane to 150 mm above the upper edge
of the Profile (flashing on request).
System example: VA.8.95/52 F W1

Fitting Floor-Wall connection W1
if the expansion joint passes offset to rising building components,
there is at the transition from floor-floor to floor-wall
one Profile fitting required. A straight (aligned) profile is therefore given.
System example: VA.8.95/52 F W1

Floor-Wall constructions W2
Profile design Floor-Wall connection W2
for expansion joints on rising building components with
mounting bracket downwards.
Installation only possible from profile height of approx. 60 mm.
System example: VA.8.95/60 W2

Fitting Floor-Wall connection W2
if the expansion joint passes directly on rising building components,
there are at the transition from floor-floor to floor-wall
two corner pieces horizontally required (Z-shaped design).
System example: VA.8.95/60 W2

Floor-Wall constructions W3
Profile design Floor-Wall connection W3
for expansion joints on rising building components with mounting
bracket upwards.
Raise of the waterproofing membrane to 50 mm above the
upper edge of the Profile.
System example: VA.8.95/20 W3

Fitting Floor-Wall connection W3
if the expansion joint passes directly on rising building components,
there is at the transition from floor-floor to floor-wall
one Profile fitting required. A straight (aligned) profile is therefore given.
System example: VA.8.95/20 W3

Floor-Wall constructions W4
Profile design Floor-Wall connection W4
for expansion joints on rising building components with mounting
bracket upwards.
Raise of the waterproofing membrane to 150 mm above the
upper edge of the Profile.
System example: VA.8.95/52 F W4

Fitting Floor-Wall connection W4
if the expansion joint passes directly on rising building components,
there is at the transition from floor-floor to floor-wall
one Profile fitting required. A straight (aligned) profile is therefore given.
System example: VA.8.95/52 F W4

Floor-Wall constructions W5
Profile design Floor-Wall connection W5
for expansion joints on rising building components with mounting
bracket upwards.
Raise of the waterproofing membrane to 150 mm above the
upper edge of the Profile (flashing on request).
System example: VA.8.95/52 F W5

Fitting Floor-Wall connection W5
if the expansion joint passes directly on rising building components,
there is at the transition from floor-floor to floor-wall
one Profile fitting required. A straight (aligned) profile is therefore given.
System example: VA.8.95/52 F W5