Installation example on formwork

BUPROFILE watertight VA.8.95/0 with grouting profile VP5/20

1. height adjustment of the 1st profile half by fixing to formwork.

2. After concreting, attach the second half of the profile using spacers. Subsequent concreting.

3. Before applying the coating, remove the spacer and the VP5/20 grouting profile. Install the sealing membrane (Wolfin) as well as the expansion insert and grout using stainless steel cover caps and countersunk screw M8 at a distance of 150 mm.

4. applying the coating:
For coating systems OS8, OS11 and OS13, the floating layer is applied flush with the surface in the open grouting joint. For coating system OS3, please request technical advice.